Caspar Cervical Distractor



They also have a 10% wider diameter than typical distractions pins for increased durability and complete surgical con. All instruments are crafted from German stainless steel. Description. Post-Procedure: Anterior Cervical Arthrodesis (Smith-Robinson Technique) POST-PROCEDURE CARE. *We respect your privacy and do not tolerate spam. spine surgery requirements - anterior (fmc) cervical sets - anterior or table / positioning equipment caspar retractor/distractor (5) xia anterior (1). In general, it is difficult to use rods to provide significant compression or distraction in the ventral cervical spine as can be easily achieved in the thoracic and lumbar spine. Caspar Distractor Right Drill guide for parallel positioning of the distraction screws. Patented Sure-Lock technology ensures that the retractor blades are securely attached. Aesculap ff906 casper driver for distraction pins 200mm we are selling a screwdriver model : overall length: 7-3 4 inches this item is used and in good condition. Source from M. The screws for CASPAR distractor should be of 2. The embodiment shown in FIG. Sofield retractor Set 9" DE, set of 6 with clip (gS 36. Frankel classification A complete loss of motor end sensory functions B no motor preservation, sensory function only C useless motor function preserved. Buy cervical spine instruments including Cloward blade retractors, Caspar distractors and more at Millennium Surgical Instruments. The AP diameter or the extent of the disc space was measured in the midline. mis distractor Smaller sleeker design for use with most tubular or "MIS" retractor systems. The graft was stable to pull-out forces. Subsequent distraction then causes the facets to disengage. OLUŞUM SURGICAL INSTRUMENS INDUSTRY AND TRADE COMPANY Caspar Cervical Distractor System Microdiscectomy Instruments Hospital Slippers: Catalog 2013. We routinely use Caspar distractor pins to open the disc space during anterior cervical Fig. Sample Name: Anterior Cervical Discectomy & Fusion - 7 Description: C4-C5, C5-C6 anterior cervical discectomy and fusion. (B) When the Caspar distractor is placed over the pins, it brings them into parallel alignment and reduces the lordosis. Description. this step also allows for restoration of segmental lordosis, if desired. The Caspar Cervical Distractor System offers precision designed instrumentation and techniques that are considered the gold standard in cervical distraction. This innovative technique allows controlled decompression while maintaining dorsal bony architecture and protecting the spinal canal, permitting fusion with a traditional posterior stabilization system. CASPAR CERVICAL DISTRACTOR SYSTEM Over 25 years the Caspar Distractor System is considered as the first choice technology for cervical distraction procedures. 7 mm dia and length should be 14 and 16 mm. Email any questions to priscilla. Huge Collection of Windows, Doors, and Salvage. AESCULAP FF 893 Caspar Vertebral Body Distractor. We use cookies on this site to enhance your user experience. Discover clearance sale on Pakistan Driver - we carry wide range of Pakistan Driver. Copyrights © 2018 All Rights Reserved. com CASPAR Cervical Retractor System Product Overview The CASPAR Cervical Retractor System is used for soft tissue retraction in anterior cervical discectomy and fusion procedures. Ltd, Suzhou, China) followed by a total C3/C4 discectomy and removal of the cartilaginous endplates with a high-speed drill to reveal bleeding bone, which resulted in an excision of ~1 mm of each endplate. We are committed to serve our customers with cheap Orthopaedic Instruments deals. Each Caspar pin was placed in the center of the upper and lower vertebral bodies. 1026 left drill guide Caspar Distractor Left 40. In cases of segmental instability, supplemental internal fixation using a cervical plating system should be considered. (B) When the Caspar distractor is placed over the pins, it brings them into parallel alignment and reduces the lordosis. on Alibaba. Provides a complete guide to all contemporary forms of spinal implant systems. Reduction is achieved and then maintained using rigid cross-fixation. 1020: Caspar Distractor Left body 3 1/4. These procedures are performed to relieve neck, arm,a nd hand pain due to herniated discs and/or bone spurs that impact the nerves and cause compression of the spinal cord. mis distractor Smaller sleeker design for use with most tubular or "MIS" retractor systems. Like AESCULAP Distractor FF 891 R (not included) but with elongated toothed bar, for multilevel (more than 2) distraction. Review (mpn: u44-627-10 for sale) U44-627-10 Synthes Caspar Cervical Drill Guides Left U44-637-10. Featuring Neurosurgical in stock here online!. We have failed to confirm that any bony fusion in the true sense occurs with Kiel bone in anterior cervical interbody fusion. They also have a 10% wider diameter than typical distractions pins for increased durability and complete surgical con. Caspar Cervical Distractor Right Sklar's® Caspar Cervical Distractor is an orthopedic speciality instrument for use in neurosurgical procedures of the spine and cervical spine. The right Caspar Vertebral Distractor is used in anterior cervical discectomy to move the vertebral body and enhance surgical exposure for subsequent decompression and proper graft insertion. Zabeel Industries is well known as Real Manufacturer and Exporters/Suppliers on wholesale as well as retail of Surgical, Dental, Beauty, Orthopedic, Veterinary instruments & Holloware. distractors were placed into the body of C6 an C7, and then another x-ray was obtained, which helped confirm the level of the procedure. in Caspar Cervical Distractor (CCD), Caspar Cervical Retractor (CCR), Minimally Invasive Equipment, Vertebral Augmentation Systems, Hand Tools / Surgical Instruments, Drivers / Screw Drivers 1520 Tradeport Drive Jacksonville, Florida 32218-2480 United States of America. 25 Neuro Spine Caspar Cervical Retractor Complete Set Orthopedic Instruments Zimmer Orthopedic Spine - $275. In cases of segmental instability, supplemental internal fixation using a cervical plating system should be considered. A window is then made corresponding to the size of the implant. aesculap caspar cervical retractor instruments w/sterilization case 1 - jk440/jk489 aesculap sterilization case 1 - ff891r cervical distractor - right. The graft was stable to pull-out forces. Unique lighting system provides direct. com Professional Instruments for Professional Users. For stability this self-retaining design requires equal tissue counterpressure. This technique enhances surgical exposure for subsequent decompression and allows graft insertion 1 - 4). Caspar Cervical Retractor Clear-Line TL. Note: tests should only be performed by a properly trained health care practitioner. Frankel classification A complete loss of motor end sensory functions B no motor preservation, sensory function only C useless motor function preserved. • Caspar Distractor system • Straight Lamina Spreader • Bayonet Lamina Spreaders • Curved Lamina Spreaders • Cloward Cervical Spreaders • Classic Cervical Spreader; Nerve Retractors • Love Retractor, Bayonet • Love Hook, 5 mm • Love Hook, 3 mm • Scoville Hook • Holsher Root Retractor • Dandy Nerve Hook • Cushing Nerve. Novo Surgical's Caspar Cervical Vertebral Body Distractor is a specialized instrument crafted for use in neurosurgical procedures, specifically those of the spine. If there is a major discrepancy or blatant misrepresentation we will be more than happy to discuss the issue with you. You are encouraged to confirm that the manufacturer item code above matches the product you seek. Williams Discectomy retractor 7" 10x70mm right, gs40. Send us email: [email protected] Retractors and Caspar distraction pins were placed at the appropriate levels. The Caspar Cervical Retractor System was developed over 20 years Caspar Distraction Pins For use with Caspar Distraction System Caspar Retractor. 2017 Spine CPT Code Changes By: Kim Pollock, RN, MBA, CPC, CMDP Spine surgeons face a multitude of Current Procedural Terminology® (CPT) code changes, effective Jan. Cervical Set Distractor Caspar With Orthopedic Driver Screws Instruments Instruments Screws Driver Cervical With Set Orthopedic Caspar Distractor $142. If using a caspar distractor, the pins should be placed approximately 7 mm from both endplates to avoid contact between the caspar pins and ROI-C anchoring plates during insertion (Figure 2). Should insertion prove difficult, pre-drill a hole for the screws using the 1. A standard discectomy was. body and interoperative x-rays were taken to verify levels. Pre-contoured plates that conform to the natural lordotic curvature of the spine are available in one and two level configurations. The Southern Medical Caspar Distractor offers a low profile and sturdy instrument to distract the cervical vertebrae. Available in 12 mm, 14 mm, 16 mm, 18 mm. The device consists of a polyethylene core articulating with two metal endplates. mis distractor Smaller sleeker design for use with most tubular or "MIS" retractor systems. A typical ante-rior approach to the cervical spine was performed. Caspar Distractor Right Drill. Post-Procedure: Anterior Cervical Arthrodesis (Smith-Robinson Technique) POST-PROCEDURE CARE. Les broches doivent être parallèles entre elles et parallèles aux plateaux vertébraux afin d'assurer une distraction parallèle. this step also allows for restoration of segmental lordosis, if desired. The Caspar Cervical Distractor System offers precision designed instrumentation and techniques that are considered the gold standard in cervical distraction. 8" (203 mm) MX 96-0139 right body, 2 1/2" spread MX 96-0140 right body, 3 1/4" spread, long bar MX 96-0147 right drill guide black Radel handle. 160 Pan Head Screw Set For Dock Bumper Marine Grade Stainless Steel 10 X 1-14. Send us email: [email protected] The SECURE®-C Cervical Artificial Disc device is an innovative artificial disc designed to alleviate pain and preserve motion in patients with symptomatic cervical disc disease (SCDD). These injuries can be simplified into Uni-facetal dislocations, Bi-facetal dislocations or Facet. Browse 68 drivers available for sale here. These patients were prospectively studied. Multiple lighted blades. If a Caspar distractor has been used, the distraction can now be released and the introducer removed from the STALIF C™. The Anterior Cervical Distractor System includes a cervical distractor having a distracting assembly for distracting vertebral bodies and a centering assembly for providing proper alignment. 2 Tape is placed across the patient's forehead ( A ) and secured to the operating table ( B ) to maintain the cervical spine in neutral alignment. 26cm Smaller sleeker design for use with most tubular or "MIS" retractor systems. After exposing the cervical spine, the distraction pins are placed midline in the vertebral bodies adjacent to the level to be treated. This is often done in order to place a graft or other interbody fusion device in the spine. The dorsal longitudinal ligamentum was completed resected. This complete Caspar style tubular distractor set is considered the gold standard in cervical disc distraction procedure. We placed Caspar self-distraction pin and gently distracted the disk space. A simplified technique for anterior cervical discectomy and fusion using a screw-plate implanted over the Caspar distractor pins Article (PDF Available) in Acta orthopaedica Belgica 76(4):546-8. 5 cm) 416-230 Caspar Cervical, Vertebral Retractor • for use with the titanium and plastic quick release blades only • double articulation • 100 mm maximum spread • 6 1/4˝ (16 cm) 416-250. The responsibility is between customer and carrier. Novel experimental techniques using PMHS and CT scans to assess performance of wearable sensors for mild Traumatic Brain Injury applications for different populations Conference proceedings International Research Council on the Biomechanics of Injury, IRCOBI. Caspar Cervical Retractor Clear-Line. Specifications. Dynamic Radiographic Criteria for Detecting Pseudarthrosis Following Anterior Cervical Arthrodesis Kwang-Sup Song, MD, Chaiwat Piyaskulkaew, MD, Tapanut Chuntarapas, MD, Jacob M. All the threads of the pins should be engaged in. Caspar Cervical Retractor System Clear Line SBH offers the high quality Caspar Cervical Retractor System Clear Line. Prefixation Pins can be used to assist positioning and to stabilize the plate in the midline prior to screw insertion. Caspar distraction pins can be used within the retractor to open the disc space as needed during discectomy (not shown). This was press fit with demineralized bone matrix and tamped firmly into position achieving excellent interference fit. Cervical Spondylomyelopathy (Wobbler Syndrome) What is cervical spondylomyelopathy (wobbler syndrome)? Cervical spondylomyelopathy, commonly referred to as wobbler syndrome , is a disease of the spine within the neck, resulting in poor transmission of nerve signals between the brain and the body. Once you know about incised and caspar as they relate to cervical surgery, you can begin to understand distractors. QADEER & NASEER SURGICAL CO. 20,28,32 These include discectomy, distraction of the affected space with a Caspar cervical distractor, inserting in the distracted space either a cancellous bone allograft20 or a cortical ring allograft to promote fusion28, and fixing the vertebrae of the affected. A wide variety of orthopedic distractor options are available to you, There are 1,231 orthopedic distractor suppliers, mainly located in Asia. Descubre la mejor forma de comprar online. 5 cm) 416-230 Caspar Cervical, Vertebral Retractor • for use with the titanium and plastic quick release blades only • double articulation • 100 mm maximum spread • 6 1/4˝ (16 cm) 416-250. Cervical Distractor Right (View Details) Add to Quote. The distractor set is used to place distraction pins in the cervical area into the vertebral bodies of the affected pathology, simply place the distractor over the seated pins, and distract to perform the discectomy. The distractor 10 is used as follows: The surgeon would make the incision and open up the cervical interspace and the tips of the distractor would be inserted into the space. Available in 12 mm, 14 mm, 16 mm, 18 mm. com Professional Instruments for Professional Users. A microscope was used during exposure and throughout the remainder of the case. There was some retrolisthesis at C5-6 and we again used the bur and burred down this posterior and inferior portion of C5. Caspar Retractor, Right. Skin incision is the same, you can probably reach 3 (or even 4?) levels with a 4 cm horizontal neck collar incision. 2017 CERVICAL & LUMBAR Micro Instruments. In surgery of the cervical spine, a Caspar pin distractor is often used to apply a tensile load to the spine in order to open up the disc space. Pins snapped off at exactly the same position. Collectible Entertainment Winter is Coming - Get Your Entertaiment Collectibles, TV Props, Movie Props and More, Right Here!. Arion Caspar Distractor-Caspar Pin (Figure 3: ARN-CD-9019 ARN-PN-9021) Surgical Technique It is recommended that pins should be driven at least 5. Copyrights © 2018 All Rights Reserved. Cervical spondylotic myelopathy (CSM) is a syndrome describing a wide spectrum of degenerative changes within the cervical motion segments that ultimately result in spinal cord compression at one or more levels. Caspar Distractor Set, with either fixed or articulating, adjustable distractors A selection of distractors, drill guides (left & right) and the Caspar Distractor Screwdriver to fit all Distraction Screws Caspar Lumbar Microdiscectomy Retractor System A microsurgical approach to retract the posterior soft tissues during micro lumbar discectomies. Pre-contoured plates that conform to the natural lordotic curvature of the spine are available in one and two level configurations. males, average 62,5 yr) underwent cervical corpectomy. The Smith-Robinson anterior cervical approach was used, and the target level was confirmed by a lateral view radiograph. Specifications HPIS Code: 710_920_30_0. Cervical facet fractures and dislocations are osteoligamentous injuries of the cervical spine. The modern era of cervical spine surgery in treatment of cervical instability began with the reports of Roy-Camille [70, 72] who treated spinal instability with plates and screws inserted in the lateral masses. For left side approach. The separation of the movable legs would be determined and they would be moved within slots 38 and 40 until the proper size was obtained. Gradual distraction is achieved under lateral fluoroscopic monitoring until the dislocated facet is unlocked. They also have a 10% wider diameter than typical distractions pins for increased durability and complete surgical con. The pins should be placed in the upper half of the superior. The distractor set is used to place distraction pins in the cervical area into the vertebral bodies of the affected pathology, simply place the distractor over the seated pins, and distract to perform the discectomy. The Caspar Cervical Distractor System offers precision designed instrumentation and techniques that are considered the gold standard in cervical distraction. Anterior cervical discectomy with fusion is a common surgical procedure for patients experiencing pain and/or neurological deficits due to cervical spondylosis. Biggest collection of 68 drivers at reasonable asking prices. Bracing and mobilization vary by technique: Smith-Robinson or Simmons' technique: rigid cervical orthosis for 4 to 6 weeks (discectomy) or 8 to 12 weeks (corpectomy); soft cervical collar for an additional 1 to 2 weeks. Brochure 25. They should be inserted in the middle of the vertebral bodiesÕ over- and under-lying the discal space to be treated and parallel to the endplates. Hay proveedores de 339 columna cervical retractores, principalmente ubicados en South Asia. Review (mpn: u44-627-10 for sale) U44-627-10 Synthes Caspar Cervical Drill Guides Left U44-637-10. Caspar Cervical Retractor 23. The Smith-Robinson anterior cervical approach was used, and the target level was confirmed by a lateral view radiograph. The MaxAn One Anterior Cervical Plate System is an anterior cervical spinal fixation device made from titanium alloy (Ti-6Al-4V). The Anterior Cervical Discectomy fusion retractor system is commonly used in cervical spine and cervical distraction procedures. Novo Surgical's Caspar Cervical Vertebral Distractor Drill Guide is crafted for use alongside the Casper Cervical Vertebral Distractor. For right side approach. You are encouraged to confirm that the manufacturer item code above matches the product you seek. is a surgical instrument company which concentrates on the manufacture and continual development of specialty lines of instruments in the following areas: Ear, Nose, and Throat, General Surgery, Laparoscopy, Neurosurgery, Obstetric/Gynecology, Ophthalmic, Orthopedic, Plastic, Table Mounted Retractors, Vascular/Cardiovascular, and Bariatric. Founded in 2003, Globus’ single-minded focus on advancing spinal surgery has made it the fastest growing company in the history of orthopedics. An interbody cage has been used to prevent donor site morbidity but there are few reports on the clinical and radiological outcome. Caspar Distractors work with all size distraction screws & caspar pins. At the one-year follow-up, the fusion rate in the n-HA/PA66 group was higher, albeit non-significantly, than that in the TMC group for both 1- and 2-level ACCF, but the fusion rates of the procedures were almost equal at the final follow-up. Self-drilling tip. Posteriorly, we inspected the facet joints using the highest-powermicroscopevisualizationwhilepryingthespinousprocessesapart with a small Cobb elevator. Traynelis VC, Ryken TC: Caspar plate stabilization of the cervical spine, in Hitchon PW, Traynelis VC, Rengachary S (eds): Techniques in Spinal Fusion and Stabilization. Request a Quote. Send us email: [email protected] The graft height is usually selected based on the preoperative radiographic data and intraoperative measurement without knowing the exact distraction load. com offers 1,235 orthopedic distractor products. This site uses cookies as described in our Cookie Policy. Perform microsurgical decompression to relieve all points of neural compression and prominent ventral spondylosis ridges, preserving the uncovertebral joints and subchondral bone as much as possible. cervical and thoraco-lumbar spine procedures Should have full set of retractors and The system should have left and right cervical CASPAR distractor with adjustable angles. CASPAR CERVICAL DISTRACTOR SYSTEM Over 25 years the Caspar Distractor System is considered as the first choice technology for cervical distraction procedures. You are encouraged to confirm that the manufacturer item code above matches the product you seek. The article discusses the most common and important devices of the head, neck, and spine. Source from M. The modern era of cervical spine surgery in treatment of cervical instability began with the reports of Roy-Camille [70, 72] who treated spinal instability with plates and screws inserted in the lateral masses. Food and Drug Administration and state and local regulatory agencies. Listings in Services and Caspar Cervical Distractor (CCD) Listings in Services and Caspar Cervical Distractor (CCD) Sponsor Area; Main navigation Menu Open Search. After Caspar distractor release, a manual pullout test confirmed the stability of the segments. These patients were prospectively studied. In order for the pins to engage the Caspar distractor, they must be brought parallel to each other which distracts and unlocks the dislocated facet. Distraction and traction was then removed and anterior cervical instrumentation was completed using a DePuy Trimline anterior cervical plate with 14-mm self-drilling screws. Self Retaining Cervical Pin Driver IN'TECH MEDICAL Cervical Pin Distractor The practical caspar distractor has been designed to pry open the vertebral bodies in ACDF SKU# S03. this step also allows for restoration of segmental lordosis, if desired. 7mm Screws for Cervical Distractor (396. Then put the 2 holes of Casper retractor into the pins driven into the vertebrae. 1022 left body 3 1/4" spread. Caspar Cervical Retractor basic counter retractor, double hinge, histal hinge titanium, radiolucent. , during anterior cervical discectomy and fusion. Cervical Retractor Handle - Small 3. An Anterior Cervical Distractor System and Technique of use for surgical procedures to correct cervical spinal deformities is described. Globus Medical, Inc. com Call 800. Symmetry® Distractor, Caspar Cervical Vertebral Body Multi-Level, Left, Stainless Steel. Caspar Cervical Distractor Right. preparation of the vertebral bodies’ contacting surfaces 18 iv. Huge Collection of Windows, Doors, and Salvage. Forty-two patients were prospectively randomized to undergo either anterior cervical discectomy and fusion or posterior fixation. Then put the 2 holes of Casper retractor into the pins driven into the vertebrae. Cervical Distractor. Caspar Pins Distraction Screws For 12mm, 14mm & 16mm Caspar Pins that are always in stock. 00 Medline Stainless Steel Anterior Cervical Distraction Screws # MDS9091212 - SCREW, DISTRACTION PIN, 12MM, STERILE, 10/Box $630. (2) Stealth Surgical Instruments ACF Micro Blade Short Teeth 14x50mm, Violet (2) Stealth Surgical Instruments ACF Micro Blade Short Teeth 14x55mm, Black (2) Stealth Surgical Instruments ACF Micro Blade Short Teeth 14x60mm, Gold (1) STEALTH SURGICAL INSTRUMENTS ACF SIDE LOADING DISTRACTOR/ RETRACTOR CASE. Reduction is achieved and then maintained using rigid cross-fixation. Caspar Distractor Right Drill guide for parallel positioning of the distraction screws. positioning of the distraction screws. Aesculap ff906 casper driver for distraction pins 200mm we are selling a screwdriver model : overall length: 7-3 4 inches this item is used and in good condition. N2 - OBJECTIVE: Classically cervical biomechanical data have been obtained using cadaver models. Legal Disclaimer : Product image(s. The journal’s Editorial Board as well as its Table of Contents are divided into 108 subject areas that are covered within the journal’s scope. 2018;2018-September:403-412. Assured Quality. , during anterior cervical discectomy and fusion. Food and Drug Administration and state and local regulatory agencies. The pins should be placed in the upper half of the superior. The use of a Caspar distractor might be useful: Þrst the cervical distraction pins are positioned using the screwdriver for distraction pin. CASPAR combined neck and head rest 22 Instruments for approach 23 CCR System (Caspar Cervical Retractor System) 24 Instruments for vertebral body distraction 26 Instruments for preparation of graft site, bone graft harvesting and impaction of bone graft 28 Instruments for plating 31 Set configurations. They also have a 10% wider diameter than typical distractions pins for increased durability and complete surgical con. It allows better visualization of the dorsal aspect of the discectomy, facilitates the. If a Caspar distractor has been used, the distraction can now be released and the introducer removed from the STALIF C™. Distraction Intervertebral decompression is achieved using the ratchet on the Caspar distractor. 00 Zimmer Orthopedic Spine Downing Laminectomy Retractor Frame W Blades 3065 201 Codman 46 3191 - $300. These offerings also range from 8. Apert, Crouzon, Pfeiffer, Antley Bixler) and midfacial retrusion. 3 - Fixation of the distraction system The patient's anatomy will determine the choice of supporting pins: choose the shortest pins. But the segmental arthrodesis leads to an overload of the adjacent disk. It not only highlights the newest devices, but also the clinical guidelines needed to choose and apply the best implant for any surgical situation. For left side approach. Cervical Distractor Right (View Details) Add to Quote. patient positioning and surgical approach 12 iv. Legal Disclaimer : Product image(s. Food and Drug Administration and state and local regulatory agencies. Distractors, Left & Right, fixed or articulating. The DePuy Synthes Companies are part of the Johnson & Johnson Family of Companies. A complete listing of changes can be found in the. Approximately two thirds of cervical spine injuries occur within the subaxial cervical spine, with fractures occurring most often at C6 and C7 and dislocations occurring most commonly between C5-C6 and C6-C7. Caspar Cervical Distractor • To maintain vertebral distraction during implantation • To allow visualization through the disc space to the dorsal longitudinal ligament Dedicated tools 19. Featuring Neurosurgical in stock here online!. When both pins are in place, distraction can be performed. ISO 13485 Certificate. Between June 1984 and April 1988, 41 patients with severe posttraumatic lesions of the cervical spine between the C2-C3 and the C7-T1 level seen consecutively were treated by an anterior cervical fusion and osteosynthetic stabilization according to Caspar. These procedures are performed to relieve neck, arm,a nd hand pain due to herniated discs and/or bone spurs that impact the nerves and cause compression of the spinal cord. Caspar Cervical Retractor Clear-Line. This step is also checked with the fluoroscope. 7mm Screws for Cervical Distractor (396. 1989) are screwed into the vertebral bodies of the affected level (Fig. Caspar cervical distractor. With distraction, the joint space is increased to relieve the pressure on the nerve roots, thus decreasing the symptoms. Each QuickStart Distraction Screw is designed for quick and easy bone penetration. The interspace was distracted using the technique for VB distraction described by Caspar et al. Clinical Notes. In order for the pins to engage the Caspar distractor, they must be brought parallel to each other which distracts and unlocks the dislocated facet. These pins anchor into the vertebra while a linear ratchet is able to distract open the disc space. 1016: Caspar Distractor Left body 2 1/2" spread. Pose des broches Poser les broches de Caspar avec le porte-broches. Huge Collection of Windows, Doors, and Salvage. Distraction and traction was then removed and anterior cervical instrumentation was completed using a DePuy Trimline anterior cervical plate with 14-mm self-drilling screws. He designed cervical lateral mass plates with 13-mm distance holes and different lengths. Presenting neurosurgical available for purchasing right now online!. The MaxAn One Anterior Cervical Plate System is an anterior cervical spinal fixation device made from titanium alloy (Ti-6Al-4V). The device consists of a polyethylene core articulating with two metal endplates. The plane between the esophagus and carotid artery was carefully dissected both bluntly and sharply down to the anterior aspect of the cervical spine. 8” (203 mm) MX 96-0169. Vertebral body distractor for use in surgical procedures from the right and from the left approach. Shop Instruments Orthopedic for sale today online!. Browse 68 drivers available for sale here. About 68% of these are obstetrics & gynecology equipments, 19% are orthopedic surgical instruments, and 3% are the basis of surgical instruments. 6101 - gS 36. Buy cervical spine instruments including Cloward blade retractors, Caspar distractors and more at Millennium Surgical Instruments. The article discusses the most common and important devices of the head, neck, and spine. Department of Neurosurgery, Nepean Hospital, Penrith, New South Wales, Australia The alarmingly high soft-tissue complication rates after anterior cervical surgery suggests that the design of current retractors is inadequate. Instruments can be purchased separately or as part of the TrimLine Set. Both Left & Right Cervical Caspar Distractors available. Caspar Cervical Distractor Lift With Screws Pins Neurosurgical Instrument Op-016. A/P "uoroscopy should be used to con!rm placement of the distractor pins in the midline. facilitate burring at an angle parallel to the disc space. Caspar retractor set, , Pakistan, MAQNSCO, MA-0627. Materials and methods A typical cervical distractor is shown in Fig. Caspar Distractors work with all size distraction screws & caspar pins. Caspar Cervical Distractor • To maintain vertebral distraction during implantation • To allow visualization through the disc space to the dorsal longitudinal ligament Dedicated tools 19. Instruments can be purchased separately or as part of the TrimLine Set. This article provides a summary of these changes so practices can get a head start on understanding their implications. This complete Caspar style tubular distractor set is considered the gold standard in cervical disc distraction procedure. For right side approach. The Southern Medical Caspar Distractor offers a low profile and sturdy instrument to distract the cervical vertebrae. Unique lighting system provides direct illumination and increased visualization. Welcome to Ascender Surgical Co. The purpose of this study was to investigate the clinical relevance of distraction force during ACDF. body and interoperative x-rays were taken to verify levels. He designed cervical lateral mass plates with 13-mm distance holes and different lengths. Two Caspar pins were placed, and the Caspar pin distractor was used to distract the interspace. Mobi-C® Cervical Disc—Surgical Technique Guide 9 Attach Caspar Distractor • Select the locking distractor (caspar distractor) 80 mm arm length in either a left or right orientation. Encuentre toda la información del producto: retractor cervical / para cirugía ortopédica Caspar Instruments de la empresa Aesculap®. Cervical Distraction. The Anterior Cervical Distractor System includes a cervical distractor having a distracting assembly for distracting vertebral bodies and a centering assembly for providing proper alignment. Featuring neurosurgical for sale here on the internet. Hay proveedores de 339 columna cervical retractores, principalmente ubicados en South Asia. Distraction was achieved with a Caspar distractor (Qingniu Medical Devices Co. Product Number: 13-7030. The distractor 10 is used as follows: The surgeon would make the incision and open up the cervical interspace and the tips of the distractor would be inserted into the space. Cervical Distraction Screw Retractor Blade 9. CASPAR CERVICAL DISTRACTIONSET Distraction Retractor For retraction of the vertebral body in the cervical spine to allow access to the disc Less instrumentation in the disc space Distraction scews are secured into the vertebral body either side of the disc, the retractor is then slid over the screws and retracted SP3002-00 Right (illustrated). This complete Caspar style tubular distractor set is considered the gold standard in cervical disc distraction procedure. 2- Caspar Cervical Distractor. This tests is performed in the presence of radicular symptoms in attempt to unload the compressed nerve and lessen the radicular symptoms. I'm with you Beachdog. 7mm Screws for Cervical Distractor (396. com Professional Instruments for Professional Users. These Distractors fit over all cervical distraction screws and have a rack length of 100 mm or 120 mm. AU - Chamberland, David. It consists of two vertebral body distractors from the right or left approach for C5 through T1/2 for the upper cervical spine. Novo Surgical's Caspar Cervical Vertebral Distractor Drill Guide is crafted for use alongside the Casper Cervical Vertebral Distractor. Les broches doivent être parallèles entre elles et parallèles aux plateaux vertébraux afin d'assurer une distraction parallèle. These implants have been designed to provide stabilization as an adjunct to cervical fusion. implant selection 15 5. CANOPY® Posterior Decompression System. He designed cervical lateral mass plates with 13-mm distance holes and different lengths. cervical and thoraco-lumbar spine procedures Should have full set of retractors and The system should have left and right cervical CASPAR distractor with adjustable angles. We have comprehensive list of Orthopaedic Instruments with detailed description and pictures from Ebay. Place it over a Prefixation Pin in the sterilization case and release the flange to engage the pin. p22999 : cloward style cervical drill guard, small 4" (10cm) p22996 : cloward style depth gauge, small p22997 : cloward style drill guard, small double-ended, 7 1/2" (19cm) p22466 : caspar retractor, lateral blade, long 65 x 23mm p22037 : cloward lamina spreader w/teeth on tips p22485 : distractor screwdriver. A few approaches to this distraction-stabilization technique have been described.